ZFSSA - Fault LED still on but No faults seen on system
The aim of this article is to clear a continually lit fault LED after making sure there are no faults remaining on the system.
To view and mark repaired the faults on the Fault Management Shell (FMA faults logged to the SP):
- While still logged into the Oracle ILOM/SP, start the Fault Management Shell
-> start /SP/faultmgmt/shell
- View faulted components
faultmgmtsp> fmadm faulty
- For each fault listed, run the repair command
faultmgmtsp> fmadm repair <UUID>
- Log out of the shell
faultmgmtsp> exit
To clear fault events and reset ILOM/SP:
- ssh to the ILOM as root ILOM user
-> cd /SP/logs/event -> set clear=true Are you sure you want to clear /SP/logs/event (y/n)? y Set 'clear' to 'true' -> reset /SP Are you sure you want to reset /SP (y/n)? y Performing reset on /SP